The results show average values of 3. 07MPa m and 2. 85 kJ
m2
for pure mode I fracture toughness and pure mode I CSERR
respectively. As discussed in the failure model, to calculate the
values of CSERR mechanical properties (E and ν) of epoxy is
required. These properties were measured using tensile testing
and are summarized in Table 1.