Failure to achieve a reduction with this regimen for insulin should prompt a check of intravenous access, all connections, and the infusion device. If no mechanical cause is found a ailure to respond may represent untreated infection or inad- equate volume replacement. An additional bolus of insulin (equivalent to the previous hourly rate) should be given and the infusion rate doubled.