The LAMP assay showed high specificity for E. amylovora and was able to detect up to ×103 cfu/ml bacterial concentrations. The qPCR assay was also able to detect bacterial cells up to ×10−3 cfu/ ml bacterial concentration with highly specific E. amylovora detection. Grower surveys and comparative cost-benefit analysis indicated that immunoassay kits are less expensive, easier to use, and require less technical expertise for on-site fire blight diagnosis than LAMP and qPCR. However, the choice of a specific diagnostic assay depends on the time, sensitivity, and specificity required for the detection of fire blight and its management.