Figs 3 and 4 show SEM images of the fractured surface. The figures show cleavage fracture and put in evidence that the failure was brittle fracture. These two pictures are representative of the entire fracture surface. We could not observe any sign of fatigue failure. Therefore, fatigue is eliminated from the list of possible causes of the failure.