The efficiency of the proposed converter with magnetic coupling
is equal to 92.2% operating with input voltage equal to
15V, output voltage equal 300V, and output power equal 100W.
The commutation losses of the proposed converter with magnetic
coupling are reduced due to the presence of the transformer
leakage inductance and the secondary voltage multiplier that operates
as a nondissipative clamping circuit to the output diode
voltage.