The average inductor current (in each high-frequency
switching cycle), which charges the bulk capacitor, is
controlled to be proportional to the utility line-voltage
waveform. For proper operation, the output voltage must be
higher than the peak value of the line voltage and the current
drawn from the line at any given instant must be proportional
to the line voltage [1].