The interpretation rules developed by Guided Ultrasonics Ltd. (GUL) and given to inspectors during GWT training form the basis of the methods used for the evaluation of touch point corrosion. Identifiable reflections from welds are used to calibrate the DAC levels and the results are classified into severity groupings based on the estimated wall loss range.