From a semi-batch test, where periodically the supernatant
is withdrawn and a volume of suspension is added, the sediment
surface can be obtained and consequently the design
values of the unit area and the sediment height of continuous
thickeners can be deduced, thus extending the intervals
of the parameters that can be deduced from batch testing.