Aqueous A at a concentration CAO = mol/liter is introduced into a batch
reactor where it reacts away to form product R according to stoichiometry
AR. The concentration of A in the reactor is monitored at various
times, as shown below:
t,min 0 100 200 300 400
CA,mol/m3
For CAO = 500 mol/m3
batch reactor.
1000 500 333 250 200
find the conversion of reactant after 5 hours in the