3.6. Sorption of nitrogen
Nitrogen isotherms were measured using an ASAP 2020 (Micromeritics, Surface area and Porosity Analyzer Norcross, GA, USA) at −196 °C. The samples were outgassed at 120 °C to vacuum 10−4 Torr before the measurements. The surface area, SBET (Brunauer–Emmet–Teller method was used), the micropore volume, Vmic (calculated using the Dubinin–Radushkevich approach) the mesopore volume, Vmes, the total pore volume, Vt (calculated from the last point of the isotherms based on the volume of nitrogen adsorbed) were calculated from the isotherms. The volume of mesopores, Vmes, represents the difference between the total pore volume and the micropore volume.
3.7. SEM/EDX
Scanning electron microscopy images were obtained using a Zeiss Supra 55 VP with an accelerating voltage of 5.00 kV. Scanning was performed in situ on a powder sample. SEM images with energy-dispersive X-ray (EDAX) analysis were obtained in the same instrument.
3.6. Sorption of nitrogen
Nitrogen isotherms were measured using an ASAP 2020 (Micromeritics, Surface area and Porosity Analyzer Norcross, GA, USA) at −196 °C. The samples were outgassed at 120 °C to vacuum 10−4 Torr before the measurements. The surface area, SBET (Brunauer–Emmet–Teller method was used), the micropore volume, Vmic (calculated using the Dubinin–Radushkevich approach) the mesopore volume, Vmes, the total pore volume, Vt (calculated from the last point of the isotherms based on the volume of nitrogen adsorbed) were calculated from the isotherms. The volume of mesopores, Vmes, represents the difference between the total pore volume and the micropore volume.
3.7. SEM/EDX
Scanning electron microscopy images were obtained using a Zeiss Supra 55 VP with an accelerating voltage of 5.00 kV. Scanning was performed in situ on a powder sample. SEM images with energy-dispersive X-ray (EDAX) analysis were obtained in the same instrument.
การแปล กรุณารอสักครู่..
3.6 การดูดซับไนโตรเจนไนโตรเจนสมดุลย์
วัดโดยใช้ ASAP 2020 ( สหภาพมาลายา พื้นที่ผิวและความพรุนวิเคราะห์ Norcross , GA , สหรัฐอเมริกา ) − 196 องศา จำนวน outgassed 120 ° C vacuum 10 − 4 ทอร์ก่อนการวัด พื้นที่ผิว sbet ( brunauer –เอ็มเม็ตต์–เทลเลอร์ได้ใช้วิธีการ ) , micropore ระดับเสียงvmic ( คำนวณโดยใช้วิธีการ dubinin – radushkevich ) mesopore กําหนด vmes , ปริมาณรูพรุนทั้งหมด , VT ( คำนวณจากจุดสุดท้ายของสมดุลย์ขึ้นอยู่กับปริมาณของไนโตรเจนที่ถูกดูดซับ ) คำนวณจากสมดุลย์ . ปริมาณของ mesopores vmes , แสดงให้เห็น ความแตกต่างระหว่าง รวมปริมาตรรูพรุนและ micropore เล่ม
3.7 SEM การวัด
การสแกนภาพกล้องจุลทรรศน์อิเล็กตรอนได้ใช้ Zeiss Supra 55 VP กับเร่งแรงดันของ 5.00 กิโล . การกระทำในแหล่งกำเนิดในผงตัวอย่าง จากภาพรังสีเอกซ์พลังงานกระจายตัว ( edax ) วิเคราะห์ได้ในเครื่องเดียวกัน
การแปล กรุณารอสักครู่..