Calculation of heat transfer density in microchannels will be discussed in Section 3.2. From the definition of F, it was concluded that the higher its value, the larger the maldistribution. In order to minimize maldistribution, F was constrained to be less than 0.3. In addition, due to manufacturing constraints, Hchn/Wchn was also constrained to be between 1 and 30