Finally, whereas the [0°] printing case appeared to provide the weakest tensile properties in terms of mean stiffness, elongation to fracture and UTS, any case where a printing at 90° was made ([90°] and [0°/90°]) has led to a large dispersion in the measured properties and only the case [−45°/45°] provides tensile properties which are comparable to those of the injection molded specimens,both concerning the mean measures and the dispersion of measures. As observed with FDM, the elongation to fracture is reduced but by less than 20%.