Dear sirs,
Please be informed that on November, 2016. By C-Tech have come to check vibration of the machines (Plant R-P1) they can record 257 unit the result as following ,
Vibration check on machines:
Plan : 337 Unit.
Machines operate @ Vibration record : 257 Unit.
Standby : 88 Unit.
Highlight : 4 Unit.
Issue MN : 2 Unit.
There were highlight of machines this month: 4 EA.
1. I-EM4461-A1 (HGO AIR COOLER FAN) Motor had high vibration. Due to bearing defect on motor. MN. 910005283 by T-IR-CM New Entry (Click see detail to link)
2. I-EM1457-14 (STABIL. OVHD COND.) Motor had high vibration. Due to bearing defect on motor. MN. 910005280 by T-IR-CM New Entry (Click see detail to link)
Remark; MN team changed motor's bearing on 08-12-2016
3. I-EM2508-A (Air Cooler) Motor had high vibration. Due to bearing defect on motor. MN. 920607561 by Operation New Entry (Click see detail to link)
4. I-EK2508-B (Air Cooler) Motor & Fin Fan had high vibration. Due to early stage of bearing defect and mechanical loose. MN. 920611981 by Operation New Entry ( Click see detail to link)
Condition monitoring monthly report of November 2016:
• Please see click to link. ( Click see detail to link ).
If any of you need more information, please contact me.