Fig. 1(B) shows the results obtained from oscillatory frequency sweep at a fixed stress within LVE range. SLN with 10% (w/w) lipid phase demonstrated elastic response for a whole frequency studied. However, in the low frequency region, the tendency of a decrease in G0 was observed, and the crossover of G0 and G00 was expected at the frequency below the investigated frequency.