The experiments reported above were performed in the presence of a steep, inwardly-directed Ca2 + gradient. Calcium was buffered to sub-micromolar values in the pipette medium in order to mimick physiological conditions; however, in the bath a rather high Ca2 + level (5 mM) was maintained to facilitate seal formation and preserve seals during pulse application [8].