This work is a continuation of our previous study on the
corrosion kinetics of zinc alloy powder in alkaline power
sources w12,13x. Therein we presented the gasmetric method
developed to investigate zinc corrosion and described the
set used to measure the volume of the evolved hydrogen.
The method makes it possible to minimize the influence of
various methodical factors that can affect experimental
results. We compared the obtained results with those provided
by electrochemical techniques, including alternative
current impedance technique w14x, as well as with the
storage tests results of alkaline batteries w15x. The study
confirmed the applicability of the gasmetric method for
testing zincrelectrolyte solution systems.