Are all open electrical outlets in customer area equipped with child safety protection?
Are all transforming stations and technical rooms in customer areas locked?
Are all doors leading from customer areas into restricted areas clearly signposted "Staff only" or similar?
In case of a travelator: Is clear communication installed at the entry point of each travelator informing the user of the shopping trolley/ cart maximum weight load of 130 kg and which types of trolleys are allowed on travelators?
In case of a travelator: Is the access of furniture (flat) shopping trolleys with a weight load over 130 kg to the travelators prevented during all opening hours by using either barriers or guards or by conducting individual weight load checks?
Is protective safety clothing worn and proper safety equipment or tools used depending on the work done?
If applicable: Does the store have procedures for how to act in case of an earthquake or flood ?
Does the store have procedures in place to deal with bomb threats?
The Air conditoning system tested & commissioned at -22 Weeks before the opening
Is a stretcher available?
Are all emergency exit doors kept unobstructed?
Are all emergency exit signs fully visible and unobstructed by signs and displays?
Are horizontally placed push bars mounted on all emergency exit doors in customer areas?
Do all emergency exit doors swing out in the direction of exit travel?
Are emergency exit staircases, tunnels and other evacuation routes accessible and free of combustible material and obstructions?
Are exterior emergency exit doors marked on the outside and secured in a way to ensure them not being blocked from the outside or otherwise being obstructed?
Is one megaphone placed at the entrance information desk and is the other one kept available in the security central?
Is a copy of the evacuation announcement text affixed to the megaphone?
Do written evacuation instructions exist and are they kept up-to-date and reviewed once a year?
Are "No Smoking" signs clearly posted and ashtray containers placed in exit passages leading from smoking area to non smoking section?
Is the smoking area equipped with special metal waste container with self closing metal lid?
Are safety ashtrays preventing cigarettes from falling out of the ashtray used in designated smoking areas?
Is electrical equipment properly installed, maintained and used in a way so that it does not become a fire hazard?
Are technical and electrical distribution rooms free of combustible materials?
Is it ensured that combustible material is not stored within 10m of the building or in open underground parking areas?
Are all waste containers closer than 10 m to the external wall kept in a fully closed and properly secured environment?
Is a safety distance of a minimal 1m (3.28ft) in front of or around electrical stations kept free of goods or other material?
Are fire walls and doors in exposed positions secured against damages?
Are holes for ducts, pipes, cables etc. in fire walls professionally sealed with fire retardant seals by qualified tradesman?
Are local demands regarding fire and other emergency cases, followed up?
Is the store equipped with the proper number of manual fire fighting equipment?
Is the position of all extinguishers and fire hydrants clearly marked and are they easily accessible?
Does the walking distance to any extinguishing equipment (fire extinguisher and/or fire hose reel) not exceed 25m/85ft?
Are automatic fire detectors never obstructed or their functionality impaired?
Is safety distance of at least 50cm/20in between lighting displays and combustible material adhered (exception of LEDs or energy-saving light bulbs)?
Is the minimal distance 50cm/20in between sprinkler head and stored goods kept at the top rack level (in storage rooms)?
Is the sprinkler system well-protected against damage?
Are sprinkler heads unobstructed and not impaired?
Is it ensured that nothing is suspended from sprinkler pipes?