Dear Sukit-san, Good morning. As we had a meeting internally, please kindly checking below points;------------------------------------------------------------------------------------------------------------------------a)
Please prepare indicator of methyl orange for checking ammonia solution concentration.b) We need your support when we checking the Lead (Pb) concentration by using “Atomic absorption photometer”after mixing NYCO DX-KR A.c) Could you prepare the heater system just in case because it is better temperature over 35℃ when dissolveNickel sulfate with DI water as first step of mixing DX-KR A.d) Please let us know the speck of filtering machine (speck of pump & housing size) for following steps;-carbon filtration 30min (3 turns) for DX-KR A (before add KR A-1 & 2) & DX-KR B (before add KR B-1).-filtration 30min using by 0.5µ m filter for the after mixing DX-KR A & B.*It needs 2 filtering machines for each DX-KR A & B.e) According to Ito-san information there is no “ventilation system”, but it would be dentures situation when doing mixing DX-KR B due to ammonia water.------------------------------------------------------------------------------------------------------------------------Please kindly read “NYCO DX-KR Solution Product Process” as attached. Thank you and best regards.KIZAI CorporationTakao Sueyoshi From: Takao Sueyoshi [mailto:sueyoshi@kizai-chem.co.jp]