Figure 5. Design of Instrument for Sensing Pipe. (a) Size and (b) Actual Object Without Fresnel Lens
The final prototype sensing module detect standing and moving human body at room temperature as shown in Figure 6. The assembled prototype’s size is 7mm (length) x 3mm (width) x 22mm (height). The LED was inserted as an alarm indicator in order to check the operation of the proposed prototype.