Vaskinn et al. (2004) conducted field tests on rock fill, clay and moraine embankments. Two different trigger mechanisms were used to initiate the internal erosion by two 200 mm diameter pipes. They found that the rate and mechanisms of failure were typically more resistant compared to the values given by the existing analyses and guidelines