Experiment 6: Distillation
Read pp 141-152, 157-161 and 172-173, Technique 13, in TOC, and refer to
pages 51-52, Technique 6.2, to learn about heating mantles. You will be given a mixture
of two common solvents that you will have to distill using both simple and fractional
distillation techniques. Study the figures on pages 149 and 160 carefully. View the
video: 7.3 Simple Distillation (Macroscale).
Your instructor will assign a 1:1 mixture to you. Record the names of the liquids
that are contained in your mixture. Outline the following procedure:
Assemble the apparatus for a simple distillation (see Figure 13.7 on p. 149). You
should refer to the sample set-up provided in the yellow fume hood, especially noting the
placement of clamps. Note that the position of the thermometer bulb should be right
below the opening of the three-way distillation head. Position a thermowell under the
distilling flask on a ring clamp. Should the heating become too vigorous, the thermowell
can be lowered by lowering the ring clamp. Do not grease the joints when setting up the
distillation apparatus as it may contaminate the liquids you are distilling. Attach the
vacuum adapter to the condenser using a Keck clamp. Note the direction of the flow of
water in the condenser as indicated in the figures. Water enters the condenser at the
tublature nearest the receiver (you can try hooking up the hoses “backwards” to observe
the difference). Because of the large heat capacity of water, only a small stream is
needed; too much water pressure will cause the tubing to pop off.
You will use a graduated cylinder as the receiving vessel. Place a 25 mL
graduated cylinder in a beaker of ice and position it such that the lip of the cylinder is as
close as possible to the end of the vacuum adapter. Use wooden blocks, which are
available in the support room, to raise the graduated cylinder, if necessary. If the tip of
the adapter is too far above the graduated cylinder, drops of the distillate will partially
evaporate as they fall (due to the airflow in the fume hood).
Measure 40 mL of your assigned mixture into the 100 mL round bottom distilling
flask. Add two or three boiling chips to promote even boiling. Make sure all connections
in the apparatus are tight, then turn the thermowell control knob (under the fume hood
sash) to a setting between 60 and 80. Adjust the heat until the distillate drops at a regular
rate of about one drop per second. Record the temperature and volume of the distillate at
5 mL intervals. After 25 mL of distillate has been collected, quickly replace the 25 mL
graduated cylinder with a 10 mL graduated cylinder in ice. Continue to take volume and
temperature readings until another 10 mL of distillate has been collected, at which point
you may lower the heat source to stop the distillation. Do not throw away the distillate
or the liquid that remains in the round bottom flask.
When you have completed the simple distillation, you will proceed to the
fractional distillation of the same mixture. Wait until the round bottom flask has cooled,
then pour the distillate contained in the graduated cylinders into it. Add two new boiling
chips and assemble the apparatus for fractional distillation (see Figure 13.17 on p. 160).
Refer to the sample set-up in the yellow hood. The fractional distillation must be carried
out slowly. Turn on the thermowell to heat the mixture to boiling. Once boiling starts,
turn down the power. You should see a ring of condensate which gradually rises up the
length of the fractionating column, such that the column eventually acquires a uniform
temperature gradient. Increase the heat slightly if the ring of condensate stops rising.
The vapor-condensate mixture should reach the top of the column only after several
2 minutes. Once condensation of the vapors occurs, it should continue steadily at a rate not
greater than one drop per second. Increase the heat slightly if the flow rate decreases
significantly. Again, collect the distillate in the graduated cylinders, but do not place
them in ice. Record the temperature and volume of the distillate at 5 mL intervals until
the temperature starts to rise. When you see the temperature increase, record the
temperature and volume of distillate at intervals of 0.5 or 1 mL until the temperature no
longer continues to increase. At this point, record the temperature and volume of the
distillate at 5 mL intervals until about 35 mL of total distillate has been collected. Do not
distill to dryness.
After the fractional distillation is completed, pour the contents of the graduated
cylinders and the round bottom flask into the Laboratory Byproducts jar.
Obtain data from a student who distilled the other mixture.