• Adjusting the Load Cell Calibration
– This allows for the load cell to reach “true zero load” on the downhole card. Normally performed after the system has been installed. Stored in Parameter P71
– Set to:
P71 = 20000 + [P92+(P79 / P74)]
• Optimizing the RPOC – Adjusting the POC Quadrant
– The RPOC system is more than a product, is a solution for the optimization of the well. It requires constant optimization in order to maximize the production vs inflow of the well
– Consider the number of run cycles versus the amount of idle time.
• If the unit is going into Idle Time too often, we may adjust the Position quadrant closer to bottom of stroke, or slow down pumping unit
• If the unit is not going into Idle Time, we may adjust the Position quadrant closer to top of stroke, or speed up pumping unit