The numbers of sample units to be collected in each food category are as follows: Food Category I, 60 sample units; Food Category II, 30 sample units; Food Category III, 15 sample units. Submit all samples collected to the laboratory for analysis. Advise the laboratory in advance of perishable sample shipments.
Sample analysis
The laboratory will analyze each sample for the presence of Salmonella according to methods described in this manual, or in Official Methods of Analysis (2). Take a 25 g analytical unit at random from each 100 g sample unit. When a sample unit consists of more than one container, aseptically mix the contents of each container before taking the 25 g analytical unit. To reduce the analytical workload, the analytical units may be composited. The maximum size of a composite unit is 375 g or 15 analytical units. The minimum number of composite units to be tested for each food category is as follows: Food Category I, 4 composite units; Food Category II, 2 composite units; Food Category III, one composite unit. For each 375 g composite, the entire amount of 375 g is analyzed for Salmonella.