paper is the time domain analysis. This approach
requires to determine the sequence of topological
stages for proposed circuit, formulate the differential
equations in each case and solve them.
The action of a basic R-C snubber circuit relies on
the presence of inductance in the main current path.
This inductance is usually stray from transformer
leakage or a supply. Analysis [1,2] is based on the
response of the RC portion of the LRC current with
step input, Fig. 4. The differential equations
describing circuit operation are