4.1. Weighted-average-efficiency (WAE)
The weighted average efficiency provides developers of microhydro
installations a means to quantitatively compare generation
alternatives, taking into consideration the likely percentage of time
the unit will be operating under off-design conditions. As defined
by Eq. (10), the WAE is determined at 1.0Pr, 0.8Pr and 0.6.Pr