However, there are still challenges when applying guided waves to detect and correctly classify touch point corrosion. Crucially, the accuracy of the results is strongly dependent on the training and expertise of the inspector and the testing procedures used. Thick uneven coatings and/or internal deposits can cause scattering echoes and high attenuation, which may greatly reduce the frequency-regime range of data used for the interpretation.