he vapor exiting the turbine: the regenerative ORC.
Regenerative ORC shows an increase on the Second Law efficiency
compared with the basic ORC in several cases. In some cases the
advantages related to the use of regenerative ORC cycle may be
important in terms of a decrease in brine specific consumption (5–
10%) and in terms of decrease of cooling system surface (4–19%). An
increase of efficiency of the plant is possible but mainly with some
specific operating fluids