Table 6: Geothermal resources with electricity generating.
Remarks: 1Reservoir temperature from quartz (maximum stream loss) equation
TGS = [1,522/(5.75 – log(SiO2))] – 273.15 [35] SiO2 based on the study result of CMU [2].
2Q = ƞORC mCpΔT, ƞORC is 10% [34], m is mass of flow rate, Cp is 4.18 KJ/Kg-K, ΔT is hot difference temperature at approximately 40°C [34] and density of hot string is
1,000 Kg/m3
3Q = ƞORC mCpΔT, m is 75% maximum hot spring flow rate which the minimum value is 10 times of the surface hot spring flow rate [34].