GROUND WATER QUALITY MONITORING
6. The seven (7) ground water monitoring wells designated for water quality testing are listed on Attachment A and are shown on Attachment B. The wells and piezometers for water level measurements are shown on Attachment B.
NOTE. Unless otherwise appoved by the Department, wells with high turbidities must be remediated or reinstalled to reduce the turbidity value to less than 20 NTU’s prior to sample collection. Should any ground water sample exhibit dissolved oxygen concentrations greater than 20% of oxygen saturation at the field measured temperature, the sampled well must be repurged then resampled as soon as an acceptable dissolved oxygen value has been attained unless it can be demonstrated that insitu ground water contains higher levels of dissolved oxygen. All water quality analyses will be performed on unfiltered samples unless approved by the Department.
).