Figure 1
Thermal mass in the interior absorbs the sunlight and radiates the heat at night.
In a direct gain system, the thermal mass floors and walls are functional parts of the house. It is also possible to use water containers inside the house to store heat. However, it is more difficult to integrate water storage containers in the design of the house.
The thermal mass will temper the intensity of the heat during the day by absorbing the heat. At night, the thermal mass radiates heat into the living space.
2.2.1 Direct gain system rules of thumb (Austin):
A heat load analysis of the house should be conducted.
Do not exceed 6 inches of thickness in thermal mass materials.
Do not cover thermal mass floors with wall to wall carpeting; keep as bare as functionally and aesthetically possible.
Use a medium dark color for masonry floors; use light colors for other lightweight walls; thermal mass walls can be any color.
For every square foot of south glass, use 150 pounds of masonry or 4 gallons of water for thermal mass.
Fill the cavities of any concrete block used as thermal storage with concrete or other high mass substance.
Use thermal mass at less thickness throughout the living space rather than a concentrated area of thicker mass.
The surface area of mass exposed to direct sunlight should be 9 times the area of the glazing.
Sun tempering is the use of direct gain without added thermal mass. For most homes, multiply the house square footage by 0.08 to determine the amount of south facing glass for sun tempering.
2.3 Indirect Gain
In an indirect gain system, thermal mass is located between the sun and the living space. The thermal mass absorbs the sunlight that strikes it and transfers it to the living space by conduction. The indirect gain system will utilize 30 – 45% of the sun’s energy striking the glass adjoining the thermal mass.
There are two types of indirect gain systems:
Thermal storage wall systems (Trombe Walls)
Roof pond systems
2.3.1 Thermal storage wall systems:
The thermal mass is located immediately behind south facing glass in this system.