In Figure 10 are the primary results of-an error analysis. For the two cases presented, the torque command resolution is finite and the instrument is subjected to a constant acceleration equivalent to a nominal 100 quanta (of torque). The first case assumes perfect measurements are available while there is a 20% uncertainty (scale factor error) in the measurement-for the second case.