However, the de-rating of the motor for harmonic heating, reduced cooling at lower speeds and reduced torque at higher speeds must be taken into account. It is quick and convenient to use a motor selection nomogram, an example of which will be discussed at the training course. This nomogram makes allowance for the harmonic heating and reduced cooling of the motor when used with a VVVF converter