Ionic contamination report
Status: MANDATORY
Applicable standard: IPC TM650 / 2.3.25 static extraction method §6
Specific standard:
The ionic contamination measurement is to be done and reported for each production batch.
Solvent system:
A 50% v/v 2-propanol / DI water is use.
Result: continue till asymptote.
Criterium: IPC-S-815B and ANSI/J-STD-001
Microsection analysis report
Status: MANDATORY
Applicable standard: IPC 6011
Specific standard:
Unless explicitly requested, microsection is to be done on PCB for every delivery that includes design changes. The
Microsection samples are to be provided by PCB manufacturer to GA-CML.
Horizontal cross sections are specific requirements
Solder mask quality test report
Status: MANDATORY
Applicable standard: IPC 6012
Specific standard:
Unless explicitly requested, a solder mask quality test is to be performed for each manufacturing batch.
Electrical test report
Status: MANDATORY
Applicable standard: IPC 6011
Specific standard:
Unless explicitly requested, electrical test is to be performed 100% on 100% PCB of the panel. The measurement mean
reference must be given in the report, including last calibration date if applicable.
Impedance measurement report
Status: OPTIONAL
Applicable standard: IPC 6012
Specific standard:
This is only upon explicit request. In case of RF sensitive design, Impedance of critical traces is to be measured and reported
to GA-CML. The measurement mean reference must be given in the report, including last calibration date if applicable.
The list of critical tracks is to be provided by GA-CML.