Auto Start
Where the fastening number count is not necessary. It starts to count the number of fastening automatically just after cycle
end with "0" display on the screw counter, and repeats without any cycle start and stop signal for counting. "Auto Start" can
be used for monitoring fastening OK / NG condition without counting of fastening numbers.
Start ( Continuous ON )
Scout starts counting the fastening number from the ON signal edge and keeps counting until receiving a signal OFF. If the
number reaches to the target before signal OFF, it makes the Cycle complete OK and provides Cycle end output signal.
Also it verifies the Cycle complete NG. If the ON status is turned OFF, it means the fastening work isn’t finished because the
work piece left the working area.