9. ELISA PROTOCOL
Bring all reagents to room temperature (20 - 25°C) before use.
1. Determine the number of test wells required and fill out the data collection sheet. Return
the unused strips of the HSA-MGO coated microtiter plate to the storage bag with
desiccant, seal and store at 2 - 8°C.
Please notice the amount of standards and samples with tracer (total of 250µl) in the Ushape plate is sufficient for a duplicate determination of standards, samples and
controls. Therefore, double the amount of wells for the coated microtiter plate are
needed.
2. Prepare the standard dilution series in the U-shaped plate. Prepare the samples and add
125 µl to the U-shaped plate.
3. Add 125 µl of the diluted tracer to the 125 µl of standards and samples in the U-shaped
plate. Gently mix by pipetting.
4. Cover the tray and tap the tray to eliminate any air bubbles. Be careful not to splash
liquid onto the cover.
5. Incubate U-shaped plate for 1 hour at room temperature.