NOTES
1. 1 Bar equals 14.5 psi
2. The Constance supply voltage is biased in Whetstones bridge configuration.
3. The total current using whetstones bridge configuration.
4. Full Scale Span (VFSS) is defined as the algebraic difference between the output voltage at
full
rated pressure and the output voltage at the minimum rated pressure.
5. Offset (Voff) is defined as the output voltage at the minimum rated pressure.
6. Error value of end point line fit between output minimum rated pressure and maximum rate
pressure.
7. Pressure Hysteresis: Output deviation at any pressure within the specified range, when this
pressure is cycled to and from the minimum or maximum rated pressure, at 25°C.
8. Output deviation with minimum rated pressure applied, over the temperature range of 25 to
120°C, relative to 25°C.
9. Difference output deviation with minimum rated pressure applied and maximum applied
pressure, relative to the temperature range of 25 to 120°C with temperature is 25°C.