(iv) Data from previous laboratory and/or field testing which will demonstrate the capability of the dampers and spacer-dampers and their components to limit aeolian vibration and subconductor oscillation to a safe level. This data shall include accelerated laboratory vibration tests with detailed information on the frequency,
amplitude and number of cycles to failure or limits of tests