For volatile matter (at 950 C) and ash (at 550 C) content determination, a furnace capable of high (1200 C) temperatures (type L24/12 with control panel B170, Nabertherm) was used. Elemental analysis was performed using an automatic elemental analyser (type CHN 600, LECO).