Principle of Operation
The operation principle of variable area flow meter is that fluid flow raises a float in a tapered tube, increasing the area for passage of the fluid. The greater the flow, the higher the float is raised. The height of the float is directly proportional to the flowrate. With liquids, the float is raised by a combination of the buoyancy of the liquid and the velocity head of the fluid.
Variable Area Flow meter is composed of:
Transparent taper tube
Orange color float
Bottom insert
Top insert
Union nut
Union end
O-ring
Scale
Flow level indicator
Guiding rod
Material:
Fitting : Plastic ABS
Union nut : Plastic ABS
Fixer : Plastic ABS
Float : Plastic ABS
Technical Parameter
Accuracy : 4 Temperature : 0-60 °C Pressure : ?0.6 MPa
Dimension:
Dia (DN)
mm
Model
Size
(MM)
Pipe Fitting
(DN)
Measure Range
L
D1
D2
D3
32
VAF-32
288
40
49.5
74
32/40