Openings may be of other shapes than those given
in (1) above, and all corners shall be provided with a
suitable radius. When the openings are of such proportions
that their strength cannot be computed with assurance of
accuracy, or when doubt exists as to the safety of a vessel
with such openings, the part of the vessel affected shall
be subjected to a proof hydrostatic test as prescribed in
UG-101