The
washing liquid was injected due to a pressure difference
kp between the outside and inside of the venturi throat
arising from the hydrostatic pressure of the liquid and
the static pressure of the gas flow. The water was
supplied from an overhead tank; the hydrostatic pres-
sure would be varied by using different filling levels, H.
The water flow rate ~>B was measured by means of a
magnetic flow meter.