These measurements were done for different positions and
so the inductance of the phase as a function of the rotor
position was determined (see Fig. 7). The inductance of the
motor rises from around 1mH at an unaligned position to over
7mH at an aligned position. It can be seen that the calculated
and the measured values have close correlation.