Higher reboil ratio leads to no water and
methanol in the bottom, as they are the lightest components. Also
high reboil ratio ensures methyl lactate in the condenser (and perhaps
in the plates). As no substantial amount of methanol is found
in the bottom tank the esterification reaction does not take place
down the column.