An important criterion for successful application of a clamp-on flowmeter is that the pipe material
be homogeneous in nature, to efficiently conduct sound waves between the process fluid and the
clamp-on transducers. Porous pipe materials such as clay and concrete are therefore unsuitable for
clamp-on ultrasonic flow measurement.