Step 1
Obtain a Permit-Confined Space Entry Form from Program Coordinator.
Step 2
Notify Supervisor before the Confined Space Entry
Step 3
Verify Confined Space Meter has been calibrated and is in working order
Step 4
Complete the top portion of the Permit-Confined Space Entry Form
Step 5
Ensure all rescue equipment (e.g. tripod, body-belt, lanyard) is in place prior to entry
Step 6
Monitor the confined space with the MSA 4-Gas Detector prior to entry. The entrant and attendant should sign the permit authorization section on the bottom of the permit to ensure all actions and conditions necessary for safe entry have been performed.
Step 7
Employee entering the confined space should wear the 4-Gas Detector after the pre-atmosphere test. The employee should also have a full body harness and lanyard attached to the rescue tripod. Employee shall have a radio and any other necessary personal protective equipment.
Step 8