After completion of the test of standard (STD) engine, the cylinder head and valves were coated with plasma sprayed yttria stabilized zirconia (Y2O3ZrO2) with a thickness of 0.35mm over a 0.15mm thickness of NiCrAl bond coat, as the test engine was converted to a LHR condition.