CitriSurf 3050 should be mixed with clean water (deionized or distilled water if desired) at a ratio of 1
part of CitriSurf 3050 with 7 to 14 parts of water by volume to fill the tank used so as to adequately
cover all parts to be treated. Polypropylene, stainless steel, or equivalents should be used for construction
of all tanks and devices used in the CitriSurf bath. Agitation of the solution in the tank is strongly
recommended to attain optimum results. Optimum results can be obtained with many parts by using
CitriSurf in an ultrasonic tank.