Check hole diameters are within tolerance (11.0+-1.0 and 41.0+-1.0mm) with vernier calliper.
Check glass hole locations with hand held check jig for 6000-043. 40mm and 2 x 10.5mm pins should pass through all 3 holes. If not, reject the glass and check 100% of the batch.