In this configuration, the PV array dominates the power generation
by providing 49% of the total generated power. The monthly
average share of power generation by solar panel fluctuates slightly
during the year and it is always remains between 46% and 56%. On
the other hand, the monthly average share of wind power generation
changes dramatically during the year (from 5 to 38%) and has
the maximum during the summer and minimum value during the
winter. To compensate the shortage of wind or solar power, the
biogas engine generator set delivers the remaining power demand.
The monthly average share of generated power by biogas engine
generator set changes between 23% and 42% throughout the year.
The capacity factors of PV array, wind turbine and engine generator
set are 22.3%, 17.2% and 28.5%, respectively.