These experimental results reveal that the PA–DAF process was
feasible. While PA enhanced oxygen transfer, DAF was effective for
solid/liquid separation. The operating air pressure of 0.40 MPa was
chosen as the experimental pressure in the subsequent experiments
according to the test results.